Multi-NDT Technician Rope access Level1
NDT.org Member Since: 2009
Added: 10/13/2009
Last Updated: 10/13/2009
Country:
Philippines
Status:
I am willing to Travel.
I am willing to work overseas.
I prefer permanent jobs.
Certifications
Curriculum Vitae
Jacinto Andal Ramirez
Block 12 Lot 40 Saint Dominique Street, Tierra
Verde Subdivision, Pallocan West, Batangas City
Mobile No. 0916-593-3536
Email: jhack_zerimar@yahoo.com
Position Applied: NDT Multi-/Rope access Technician Level I
Summary of Experience:
Twelve (12) years experience as a Non-Destructive technician, mostly involved in Oil & Gas Refinery,
Petrochemical and other related facilities such as pipe line inspection, corrosion surveys of piping,
Pressurized vessels, power boilers, tanks and structures.Well versed in various NDT methods such as
Radiography butt and profile shot, Digital Radiography, Magnetic particle testing, dye penetrant testing
Ultrasonic Testing and Radiographic film Interpretation and evaluation using various international
code and standards.
• Experience obtained from different offshore project such as pipe line, hook-up, riser, tie-in and jacket
Installation.
• Conducted Non-destructive Testing on welders Performance Qualification Test (WPQT) based on
Applicable codes, standards and assist trainees in conducting NDT examinations.
• Knowledge in AutoCAD, isometric drawing to a very high standard.
• Knowledge in Computer such as MS word and Excel.
Qualifications
• Radiography-ASNT LEVEL II
• Digital Radiography
• Ultrasonic Testing –ASNT LEVEL II
• Magnetic Particle testing-ASNT LEVEL II
• Dye-Penetrant Testing – ASNT LEVEL II
• Rope Access Training Course-IRATA LEVEL I (IRATA No.1/26662
Training & Seminars Attended:
. Refresher Course / Re-certification on RT, MT, PT and UT ASNT LEVEL II Conducted by CAN GLOBAL LTD. at Cabinda Malongo Angola West Africa July 2007.
. Refresher Course / Re-certification on RT, MT, PT, and UT ASNT LEVEL II Conducted by OCEANEERING OIS at Cabinda Malongo Angola West Africa August 2004.
. ROPE ACCESS TRAINING COURSE LEVEL II Conducted by S.E.A. TEAM SOLUTIONS PT LTD. #3 Loyang Way 1 Singapore 508705.
. Refresher Course / Re-certification on RT, MT, PT, and UT ASNT LEVEL II Conducted by VETCO TUBOSCOPE INT’L LIMITED A VARCO COMPANY at P.O.Box 31849 Al-Khobar, 31952 (K.S.A.)
. SWING ROPE TRAINING COURSE –Conducted by HRD at Cabinda Malongo West Africa July 2006
. H2S and CONFINED SPACE TRAINING—Conducted by HRD at Cabinda Malongo West Africa
July 2006.
. Refresher Course / Re-certification on RT, MT, PT, and UT ASNT LEVEL II Conducted by AL-MUTAWA SAMYONG NDT. CO. LTD.(AMSYCO) at P.O. Box 31952 Al-Khobar
(K.S.A.) July 2000.
. BASIC RADIATION SAFETY FOR INDUSTRIAL RADIOGRAPHY TRAINING—Conducted by
Inspection Technology Center Bldg.2280 Saudi Aramco, Dharan,.November 1999.
. IN-HOUSE TRAINING FOR RADIOGRAPHY, MAGNETIC PARTICLE TESTING,DYE-PENETRANT
. TESTING AND ULTRASONIC TESTING - Conducted by FILCONFAB INCORPORATED
#8263 Constancia Street Makati City. March 1995.
. Corrosion Protection & Paint Technology Seminar—Conducted by PSPC Shell Tabangao Refinery, Tabangao Batangas City, June 1999.
. RD Tupas Consultancy (Safety Accreditation Course) —Conducted by PSPC Shell Tabangao,
Refinery Batangas City, June 1999.
. AUTOCAD 2003 - (Conducted by Informatics) Kumintang Ilaya, Batangas City
Employment History
Name of Company: CAN GLOBAL LTD.
Date Employed: September 1, 2008 up to August13,2009
Position: NDT Rope Access Inspector
Project Assignment: EXXON MOBIL EXPLORATION ANGOLA BLK.15 LIMITED
Responsibilities:
Assigned as a NDT Rope Access Inspector in offshore FPSO conducting Risk Based Inspection , corrosion monitoring of vessel, Riser inspection, piping, and plant conditioning.
Name of Company: CAN GLOBAL LTD.
Date Employed: May 1, 2007 up to September 1, 2008
Position: NDT Rope Access Inspector
Project Assignment: CHEVRON TEXACO MALONGO, ANGOLA WEST AFRICA
Responsibilities:
Assigned as a NDT Rope Access Inspector in onshore/offshore project Oil and Gas Plant for the Corrosion Department. Conducting visual inspection,Ultrasonic testing baseline survey, corrosion monitoring of vessel Riser inspection, piping and plant conditioning using DMS, EPOCH III, EPOCH IV,EPOCH LT, USM25 USM 35.
• Assigned in onshore/offshore project for the corrosion Deprtment.
• Develop marked-up mechanical flow diagrams unpaid by assigning system numbers for classified piping systems that require corrosion monitoring and/ or periodic visual inspection
• Perform RISK BASED INSPECTION (RBI) for all equipment and piping on jacket platform or process platform, by conducting ultrasonic thickness measurement survey by using ultramate, and the DMS 2 UT machine
• .Conduct visual inspection on equipments such as vessels, tanks, heat exchangers etc, as( per inspector required.)
• Gathers piping design data and actual thickness measurement readings at a predetermined locations, prepares narrative inspection history and enter them in computer main data base.
• Verify accuracy of corrosion isometric drawing and ensures that mechanical flow diagrams for each piping system are properly updated whenever any changes.addition/or deletion are noted during external visual inspection.
• Conduct profile Radiography for checking the remaining wall thickness. And finding the internal/external corrosion present
• Conduct Magnetic Particle Testing as well as Dye Penetrant Testing in all equipment and piping that require the said method.
• Prepare accomplishment reports and drawing of inspected, evaluate indications process and enterpret radiographs as per applicable codes,
standards and procedures.
Name of Company : OCEANEERING OIS INT’L LTD
Date Employed September 1, 2004 – April 30, 2007
Position: Multi-Discipline NDT Technician
Project Assignment: CHEVRON TEXACO MALONGO, ANGOLA WEST AFRICA
Responsibilities:
Assigned as a NDT Inspector on general NDT support services of oil and gas plant cnducting Ultrasonic testing baseline survey, corrosion monitoring of vessel and piping and plant conditioning using DMS2 EPOCH III,EPOCH 4 EPOCH LT,USM35 and USK 7B UT equipment.
. Assigned in onshore/offshore project for the corrosion department.
• Develop marked-up mechanical flow diagrams unpaid by assigning system numbers for classified piping systems that require corrosion monitoring and/ or periodic visual inspection
• Perform RISK BASED INSPECTION (RBI) for all equipment and piping on jacket platform or process platform, by conducting ultrasonic
thickness measurement survey by using ultramate, and the DMS 2 UT machine.
• .Conduct visual inspection on equipments such as vessels, tanks, Heat Exchangers etc, as (per inspector required.)
• Gathers piping design data and actual thickness measurement readings at a predetermined locations, prepares narrative inspection history and enter them in computer main data base.
• Verify accuracy of corrosion isometric drawing and ensures that mechanical flow diagrams for each piping system are properly updated whenever any changes.addition/or deletion are noted during external visual inspection.
• Conduct profile Radiography for checking the remaining wall thickness. And finding the internal/external corrosion present
• Conduct Magnetic Particle Testing as well as Dye Penetrant Testing in all equipment and piping that requires the said method.
• Prepare accomplishment reports and drawing of inspected, evaluate indications process and enterpret radiographs as per applicable codes, standards and procedures.
Name & Address of Co. : VETCO TUBUSCOPE INT’L LIMITED.
P.O BOX 31841 AL-KHOBAR 31952 K.S.A
Date Employed: August 24, 2003 – January 5, 2004
Position: Multi-Discipline NDT Technician
Project Assignment: Saudi Petrochemical Co. (SADAF)
Responsibilities
Performed Ultrasonic testing, Radiographic Testing Magnetic Particle Testing, Brinell Hardness Testing and Dye Penetrant Testing on pipes/boilers/vessels/ and structural welds. Perform weld Mapping and visual inspection of construction operation.
• Conduct RT/PT MT/UT on pipes and storages tanks.
• Conduct Radiographic Testing of Welders Qualification Test specimen as
• per ASME IX.
• Evaluate/Interpret the test results based on acceptable codes and standards.
• Conduct Remote Visual Inspection for welds.
• Conduct Holiday Detector for Paint Coating.
• Conduct MFL for Tank Inspection.
• Assigned in maintenance NDT Field Inspection Crew that performs corrosion monitoring on equipment and piping system using Radiographic and Ultrasonic Testing using USN 52, DMS 2 and Epoch 3 machine.
• Assist in the classification of piping System as per API-570 Code and SADAF procedure SEI-3.1
Name & Address of Co.: GMA AL-SALMEEN QUALITY CONTROL SERVICES
P.O. Box 6215, AL-Mafraq, Abu-Dhabi, United Arab Emirates.
Date Employed: Nov. 23, 2003 – Feb. 21, 2003
Position: QC INSPECTOR/NDT TECHNICIAN II
PROJECT ASSIGNMENT: As signed for the Gov’t. Pipe Line Project in Fujairah Abu-Dhabi
Responsibilities
• Conduct RT, PT, MT and UT on all spiral and butt joints weld.
• Conduct Weld Mapping
• Check/ witness the testing of welders on their pre-qualification.
• Inspection/review of isometric drawing to established that they
• Correspond to mechanical flow diagram and also to final installation.
• Conduct final Inspection and issued punch list prior to commissioning
Name & Co. Address AL-MUTAWA SAMYONG NDT. CO. LTD.
P.O. Box 31952 Al-khobar, K.S.A.
Date Employed: Sept. 17, 1999-Sept. 21, 2002
Position: NDT TECHNICIAN II
PROJECT ASSIGNMENT: Assigned as NDT Technician
.
Responsibilities
• Coordinate and deal with the clients regarding project specification.
• Recommends appropriate non-destructive testing procedures based on applicable codes, standards and specifications.
• Conduct on stream inspection (OSI) and out of service (OOSI) of fuel gas and LPG storage tank and also performed actual Ultrasonic, Radiographic, Dye Penetrant Testing and Magnetic Particle Testing of pipelines, storage tanks, super heater tubes vessels and other vertical and horizontal structures.
Name & Co. Address FILCONFAB INCORPORATED
#8263 Constancia Street, Makati City
Date Employed Nov. 1995 – Dec.1998
Position: NDT TECHNICIAN II
FIELD ASSIGNMENTS
Flour Daniel Pacific Inc. Philippines
Non-Destructive Testing Examination for the expansion of STAR project at shell refinery.
Santa Rita Power Plant, Batangas
RT/PT/MT/UT of various piping and vessel tanks.
Caltex Refinery, San Pascual Batangas
Ultrasonic, Radiographic, Magnetic Particle testing and Dye Penetrant Testing of various piping
LPG tank, vessel, super heater tubes.
Atlantic gulf & Pacific company Philippines
Radiographic Testing of various diameter piping weldments and pressure vessels as per ASME /
JIS standard.
Petron Bataan Refinery
Radiographic and Ultrasonic testing of various process piping and vessel.
Babcock Hitachi Philippines Inc. (BHPI)
Multi-Discipline technician on all Boiler coil tubes, panels, headers and vessel.
Educational Background
Tertiary : Pablo Bourbon Memorial Institute of Technology (PBMIT)
Welding Engineering Technology (DOT) Diploma of Technology
1992-1996
Secondary : Batangas National High School
1988-1992
Primary : Ambulong Elementary School
1982-1988
Personal Information
Date of Birth : July 03,1976
Place of birth : Block 12 Lot 40 Saint Dominique Street Tierra Verde Subd.
Pallocan West, Batangas City.
Sex : Male
Citizenship : Filipino
Civil Status : Married
Religion : Roman Catholic
Height : 5’10"
Weight : 80 kgs.
Passport No. : WW0109102
Education
College Graduate:Welding Engineering
Experience
12 years experience
Comments
I'am willing to accept any NDT jobs anywhere in the globe.