Mistras Group
ASNT NDT Technician Level II

To see contact info and over 12,000 resumes Get a Level II Subscription or Call (415) 796-6446.
Country: Philippines
Status:
I am willing to Travel.
Currently working but always looking.
I prefer permanent jobs.
Certifications
American Standard for Non-Destructive testing Oceaneering OIS Training Centre, UAE
Ultrasonic testing, Magnetic Particles
National training course on Non-Destructive Testing, Basic safety and emergency preparedness training, Basic offshore safety induction emergency training (Including emergency breathing equipment system
H2S and BA Donning)

American Standard for Non-Destructive testing NPC Training Centre Al- khobar, KSA
Ultrasonic testing, Radiographic,
Magnetic Particles, Visual Testing
Penetrant Testing Level II

Preventive Maintenance Philippines Society of Mechanical Engineers
15 Mar. 1996
Education
Bachelor of Science in Mechanical Engineering
Experience
Oceaneering OIS W.L.L
P.O Box 4074, Abu Dhabi UAE
As Multi Discipline NDT Technician
July 28, 2008 up to present

Jul 17 up to present
Project: Laffan Refinery Plant Qatar Gas
Location: Ras-Laffan Industrial City
Position: Multi Discipline NDT Technician
Carried out all NDT Inspection for Laffan Refinery Project under maintenance focus on corrosion monitoring inspection of Process pipe work and process plant (Vessels, Boilers, etc) using all NDT method UT,RT,MT, PT.


February 09 – Jul 16’09
Project: G.S Engineering & Construction Co. Ltd., Laffan Refinery Plant (Qatar Gas)
Location: Ras-Laffan Industrial City
Position: Multi Discipline NDT Technician
Carried out all NDT Inspection for G.S Engineering & Construction Co. Ltd., under
Laffan Refinery Project focusing on UT corrosion monitoring and RT inspection of
Process pipe work and process plant (Vessels, Boilers, etc).

September 08 – Jan 09’09
Project: National Petroleum Construction Company (NPCC PBL648 Barge)
Location: Maersk Oil Company Qatar AL-Shaheen Block 5 Field Development Project 2005
Position: Multi Discipline NDT Technician and Scanner technician
Performed AUT Scanner on pipe laying pipe 10”, 20”- 24” ф, conduct magnetic and Manual Ultrasonic testing on repaired pipe, emergency lay down head, stinger, flange ring and mechanical equipment like cranes.

August 25 – September 25 2008
Project: Maersk Oil Company Qatar (Fred Olsen Vessel Oil Tanker)
Location: North AL-Shaheen Oil Fields Offshore
Position: Multi Discipline NDT Technician
Conduct MUT monitoring of existing pipeline on cargo line, export and import line28” – 16” ф pipe line of oil tanker and coordinate with the Mearks terminal supervisor for the status of the pipeline.

National Pipe Company, Limited
P.O Box 1099 Al- Khobar 31952, Kingdom of Saudi Arabia
Oct. 5, 2001-Oct. 5, 2002 and Aug. 16, 2005 – July 11, 2008
As a Auto Line Ultrasonic testing / Multi Discipline NDT Inspector
Certified by: Mr. Leonardo L. Alarcon
ASNT Level III, Cert. No. 0092799 (UT, RT, MT, PT, VT)
Duties and Responsibility:
• Conduct daily calibration of Auto Line and Lamination testing every first T-Cross of the shift and calibration of lamination testing during the succeeding T-Cross as per standard.
• Check the accuracy and detect ability of equipment and if not, conduct re-calibration.
• Conduct regular checking of all knobs for possible loosening of probe holders nuts as well as manipulator parts. Checking of probe gaps and probe shoe and if worn-out replace if necessary.
• Monitoring of pipe quality counter checking regularly in case of any quality problems discrepancy and occurrence of injurious defect immediately ask mill stop or if necessary mill adjustment.
• Conduct M-UST as per our established standard and procedure. Conduct further M-UST of pipe as per x-ray request and checking the location of defect if requested by the welder.
• Conduct Coil inspection visual and dimensional prior to rolling. M-UST of coil top and bottom using 45˚ probes checking for scab line for laminar using normal probe.
As a VT Level II Inspector
Certified by: Mr. Pablo J. Acelajado
ASNT Level III, Cert. No. 0082577 (UT, RT, MT, PT, VT)
Duties and Responsibility:
• Shall visually inspect all pipe passing in each station of primary, re-check and final station. Strictly implementation of visual standards and rigorous inspection of pipes shall be applied at all times.
• Check inside and outside weld surface on the Spiral, Longitudinal weld seam and T-Cross weld.
• Check the inside and outside surface of the parent metal of pipes. Check pipe ends for inside bead removal and see to it that all scale and adhering flux are removed.
• Check workmanship n grinding and welding repair portion on inside and outside surface of spiral weld, longitudinal weld seam and parent metal.
• Conduct Visual and Dimensional Inspection on outside and inside welding as per API 5L 1E &2E. Checked roundness, straightness, squareness and check bevel root face.
• Conduct checking and recording of residual Stress Test pipe for the first production pipe of the shift in accordance to the specifications and standards.
As a PT Level II Inspector
Certified by: Mr. Pablo J. Acelajado
ASNT Level III, Cert. No. 0082577 (UT, RT, MT, PT, VT)
Duties and Responsibility:
• Performed penetrant testing on pipe ends, repaired joints and suspected hidden defects like scab, blister, laps and cracks as per prevailing standards and customer’s requirements.
• Conduct penetrant testing of suspected defects on Top and Bottom coil prior for rolling.
• Issued NNP on pipes with non-conformance on our standard and procedure.
• Reports and Documentation of all NDT inspection to QA/QC Group.

Dhong – Ah Consortium
Tripoli, Libya
Oct. 5, 2003 – Mar. 16, 2005
As QA/QC Mechanical Inspector
Duties and Responsibility:
• Check electrical cable, sensor bolt and nuts, gaskets and its accessories prior for installation of pumps and motors. Check bolts torque requirements and tightening sequence. Conducted Pre hydro testing of air valves, flanges and fittings, block valves, latitude valves and blow down valves prior for installation. Report immediately on damage equipment and request for replacement or repair.
• Per commissioning of all mechanical installed in chambers check and report immediately for all damage mechanical parts and its accessory for replacement or repair.
• Performed as a Coating Inspector on ductile pipes with mortar cement lining inside including PE/FBE coating, conduct holiday testing prior for pipe laying. Report any coating damages, with holidays for repair.
• Conduct Ferroxyle testing on stainless steel pipes for verification of present contamination of rust witness by the 3rd party inspector.
• Coordinate with the 3rd party inspector review all the drawing and specification. Prepare and submit the daily inspection reports.

Welders Testing Laboratory Philippines Incorporated
S-7 Sunvar Plaza Pasay Road Corner Amorsolo St. Makati City, Philippines
Aug. 16, 1996 – Aug. 20, 2001
As Multi Discipline NDT Technician
Duties and Responsibility:
• As an OIC Supervisor on two deferent projects one in UNOCAL Phil’s. Geothermal Power Plant of Makban Laguna and Shell Malampaya Batangas Phil’s. were we conduct hot radiographic and hot ultrasonic testing of online pipes to verify the life of existing pipes were no previous records on inspection. Check and submit immediately the report, conduct daily site visit on the area were RT inspection group will conduct radiographic testing make sure that the parameter is free from the non inspection group and all warning devices are place visible to the person.
• As a Coordinators verify and checks the areas especially were Gamma Ray inspection is needed. Secure working permits of all the areas concerned, make sure that all area have barricades, warning devices and make sure the area is accessible to the operators. Report any problems during site visit and during testing.
• Performed as a 3rd party inspector. Verify and checked the welding procedure, drawing, welding consumables and welders qualification records. Witness welders qualification testing.
• Conduct Ultrasonic testing on pipes, tanks and structural steel using flaw detection and thickness gauging. Prior for test verify drawing and welding preparation.
• Assigned in Deferent Geothermal Power Plants in Visayas and Mindanao Phil’s. Preformed Radiographic testing on pipes, plates and tanks in various sizes. Performed film evaluation as per prevailing codes and standard.
• Performed Magnetic particle testing on pipes, tanks and structural steel.
• Preformed penetrant testing on pipes, plates and submit all reports at the end of the work.

Picop Resources Incorporated
Tabon, Bislig City, Philippines
Dec. 15, 1995 – Mar. 16, 1996
As a Draftsman
Duties and Responsibility:
• Check and verify the actual drawing prior for layout and ordering of spare parts.
• Check visual and dimensional of spare parts as per drawings and specification.
• Make and reproduces drawings on spare parts missing or needed if not available.
• Make reports or feedback the unnecessary discrepancy of ordered spare parts
Comments
REFERENCES:

Mr. Leonardo L. Alarcon National Pipe Co. Ltd
Assistant QC Manager P.O Box 1099 Al-Khobar, 31952 K.S.A
ASNT Level III Tel No. +966502492957

Mr. Reynoso C. Dulay National Pipe Co. Ltd
UST Leadsman P.O Box 1099 Al-Khobar, 31952 K.S.A
ASNT Level II Tel No. +96655820393