Experience
25+ in Nuclear, Refinery, Power, Chemical, Pulp & Paper etc.

Empire Generating Combined Cycle Power Plant, Rensselaer, NY
Supplier Surveillance Coordinator—Responsible for major equipment for $700M project. Key Equipment included critical-BOP piping, transformers, water treatment system, gas skids, HRSG boiler & stacks, steam drums (6), steam condenser, BFW-cooling water pumps, bus duct, PDC, MCC, heat exchangers, UPS, pressure vessels, and storage tanks. Coordinated shop Inspections for 44 Purchase Orders worldwide, and developed inSpection requirement Specifications, inSpection criteria, reviewed reports, and tracked budget.

Confidential Client Chemical Plant, Belle, WV
Supplier Surveillance Coordinator—Responsible for major equipment including SS pressure vessels (66), storage tanks (8), heat exchangers, pumps, silos, conveying system, heaters, coolers, desiccant system, and structural steel. Coordinated shop Inspections for 23 Purchase Orders, developed inSpection requirement Specifications, inSpection criteria, reviewed reports, and tracked budget.

Chemical Carbon Fibers, Piedmont, SC
Supplier Surveillance Coordinator—Coordinated shop inSpection for Purchase Orders and Polymer Reactor. Acted as liaison between the shop (China) and CH2M for fabrication documentation.

Glaxo-Smith-Kline, Clifton, NJ
Supplier Surveillance Coordinator—Coordinated shop inSpection for Purchase Orders and FRP Vessels (8). Performed shop Inspections for quality, PO/Spec/Code adherence and delivery.

Valero, San Antonio, TX
QA/QC/CWI—Performed shop Inspections for quality, PO/Spec/ Code adherence and delivery on Provers.

QA Auditor/CWI—Responsible for ensuring construction contractor compliance with PO’s, Shell Specifications & code compliance. Developed audit forms & performed audits of the Construction Contractor concerning: Perform audits of Pipe Welding-Installation, Structural Steel Welding-Bolting, Documentation; CWI Inspections. Over 70,000' of pipe installed. Project on time and significantly under budget. Safety award given to project by Shell Corporate,
Comments
DETAILED EXPERIENCE

1. Shell Puget Sound Refinery - Benzene Reduction Project - Anacortes, WA
Codes Worked to: ASME, AWS, API, AISC, SSPC, ASTM, ASNT, OSHA
QA Auditor/CWI: Ensuring construction contractor compliance with PO’s, Shell specifications & Code adherence. Develop audit forms & perform audits of the Construction Contractor concerning: Pipe Installation – Welding – Fit-up; Structural Steel Welding-Bolting; Documentation-Reporting; CWI Inspections. Over 70,000' of pipe installed. Project on time and significantly under budget. Safety award given to project by Shell Corporate

2. Empire Generating - Combined Cycle Power Plant - Rensselaer, NY
Codes Worked to: ASME, AWS, API, SSPC, AISC, ASTM, ASNT, NFPA, OSHA
Supplier Surveillance Coordinator: Responsible for major equipment on $700M project. Key Equipment included Critical-BOP piping, transformers, water treatment system, gas skids, HRSG boiler & stacks, steam drums (6), steam condenser, BFW-cooling water pumps, bus duct, PDC, MCC, heat exchangers, UPS, pressure vessels, and storage tanks. Coordinated shop inspections for 44 Purchase Orders worldwide, and developed inspection requirement specifications, inspection criteria, reviewed reports, and tracked budget.

3. Confidential Client - Chemical Plant - Belle, WV:
Codes Worked to: ASME, AWS, API, SSPC, AISC, ASTM, ASNT
Supplier Surveillance Coordinator: Responsible for major equipment including SS pressure vessels (66), storage tanks (8), heat exchangers, pumps, silos, conveying system, heaters, coolers, desiccant system, and structural steel. Coordinated shop inspections for 23 Purchase Orders, developed inspection requirement specifications, inspection criteria, reviewed reports, and tracked budget.

4. Confidential Client - Chemical Carbon Fibers - Piedmont, SC
Codes Worked to: ASME, ASTM, ASNT
Supplier Surveillance Coordinator: Coordinated shop inspection for 1 Purchase Order - Polymer Reactor. Acted as liaison between the shop (China) and CH2M for fabrication inspection requirements & documentation

5. Glaxo-Smith-Kline – Shutdown - Clifton, NJ & Valero – PV - San Antonio, TX
Codes Worked to: ASME-RTP-1, ASTM, ASME; API-1104; AWS; AISC
Supplier Surveillance Coordinator & Inspector: Coordinated shop inspection for 1 Purchase Order - FRP Vessels (8). Performed shop inspections for quality, PO-Spec-Code adherence and delivery. Performed shop inspections for quality, PO-Spec-Code adherence and delivery on Provers (4)

6. Various Clients – Baghouses - Owing Mills, MD
Codes Worked to: ASME, AWS, SSPC, AISC, ASTM, ASNT
QA-QC-CWI Inspector-Auditor: Performed shop inspections for quality, PO-Spec-Code adherence and delivery. Key equipment included baghouses, precipitators, venturis, and structural steel.

7. Georgia Power/Plant Wansley - FGD Project – JBR System - Carrollton, GA
Codes Worked to: ASME, NBIC, ASTM, ASNT
QA-QC-CWI Inspector-Auditor: Site QC, FRP for jet bubble reactor, structural steel, welds, and bolts.

8. Marathon Refinery T/A – NBIC Modification - Ashland, KY
Codes Worked to: ASME, NBIC, ASTM, ASNT
QA-QC-CWI Inspector: Site QC and surveillance of "R" code repair (ASME/NBIC) on cladded pressure vessels.

9. Various Clients - Various Building Construction – Atlanta, GA ; Albany, NY
Codes Worked to: AISC, AWS, IBC, ASTM, ASNT
QC-CWI-IBC Special Inspector: Manage-review-inspection of structural steel of contracts & sub-contracted services (NDE), field inspections at constructions site for welds and bolts, audited non-AISC shops for approval prior to fabrications, performed surveillance of shop welding quality, reviewed contract documents, and developed standardized reporting.

10. Various Clients – NDE-Mechanical Services – Eastern, USA
Codes Worked to: ASME, NBIC, ASTM, ASNT, API, AWS, AISC
QC-NDE Inspector: Managed company performing NDE-Mechanical services to Pulp, Paper, Power

11. Riverbend Nuclear Station & South Texas Project – PSI – St. Francisville, LA, Palacios, TX
Codes Worked to: ASME, ASTM, ASNT
NDE Inspector: UT-RT-MT-PT inspections at 2 Nuclear Power Plants – BWR & PWR
GENERAL

Supplier Surveillance – Auditing – NDE – QA - QC of Various Materials/Equipment
Pressure Vessels – Storage Tanks – Piping – Gas Turbines – Structural Steel – Pumps - Flanges

Inspection experience with the following equipment/codes:
1. Gas Turbines: (inlet to exhaust/HRSG, GE Frame 5,6,7,9)
2. Boilers
3. Deaerators; Mud Drums, Steam Drums
4. Air Receivers
5. Condensate Tanks
6. Paper Machine Dryers
7. Pulp Equipment: digesters, flash tanks, etc…
8. FRP/Plastic Tanks
9. Piping (all classes ANSI B31.1/3)
10. PSM requirements
11. Bulk Storage Regulations
12. Structural Inspection – CWI & ICC Special Inspector
13. Electrical: PDC; MCC; Transformers
14. Distillation Columns - Refineries

Audits - Shop
Review: QC Manuals – Shop Quality – Qualifications – Procedures – Material Certifications

Audits - Field
Erectors – Sub-Contractors – 3rd Party – Contract Documents

Contract Document Review
Review: Shop – Erection – Structural – Manufacturer - drawings for accuracy & uniformity

Surveillance
Adherence to: Repair Procedures – Codes – Contract Documents – Special Inspection/ICC
Periodic – Continuous Inspections per ICC & IBC Section 17

Shop/Field Consulting
Adherence to: AISC – AWS – ASME - NBIC – ASTM Code Requirements

Consulting - 3rd Party Inspections – Special Inspections – QA/QC – Shop Audits
Structural Steel – Pressure Vessels – Storage Tanks – Piping – Gas Turbines
Field Inspection – Shop Inspection – Drawing Review – Compliance/Surveillance
Mistras Group