Mistras Group
NDT INSPECTOR MT/PT/UT/RT/ET/VT

To see contact info and over 12,000 resumes Get a Level II Subscription or Call (415) 796-6446.
State: NV Nevada
Country: United States
Status:
I am willing to Travel.
I need a job as soon as possible.
I am willing to work overseas.
I prefer temp jobs.
Certifications
ADDITIONAL INFORMATION I AM LEVEL II CERTIFIED IN MT,PT,UT,RT,AND ET WELDING AND INSPECTION. MY SKILLS INCLUDE HANDS ON EXPERIENCE IN X-RAY WITH IRIDIUM 192 AND COBALT 60 SOURCES;LONGITUDINAL AND CIRCULAR METHODS IN WET AND DRY MAGNETICAL PARTICLE INSPECTION;EDDY CURRENT AND LEAK TESTING INCLUDING VACUM BOX;ULTRASONIC INSPECTION USING LONGITUDINAL AND SHEAR WAVES;SURFACE WAVES TECHNIQUES THROUGH TRANSMISSION;THICKNESS TESTING AND BOND PERCENTS. I AM ALSO SKILLED IN THE USE OF DYE PENETRANT,ZYGLO, AND VISUAL METHODS.REGISTRATIONS:LEVEL II MT PT UT RT ET MOBILE INSPECTION 04/82LEVEL II MT PT UT RTCONTINENTAL TESTING & INSPECTION 11/85LEVEL II MT PT UT RT ETULTRASONIC FIELD SERVICES 05/86LEVEL II MT PT UTTOMAC NDT SERVICES 04/88LEVEL II MT PT RT RICHARDSON X-RAY 1988LEVEL II MT PT RTSIERRA CAST 1989LEVEL II MT PT UT RTSERGEANT,HOSKINS,&BECKWITH 1989LEVEL II RTDEFENSE SYSTEMS 1990LEVEL II MT PT UTCONTINENTAL TESTING & INSPECTION 1997LEVEL II MT PT UT RTULTRASONIC FIELD SERVICES 1997LEVEL II MT PT UT RTSGS INDUSTRIAL SERVICES 1998LEVEL II MT PT UTELITE INSPECTION 1999LEVEL II MT PT UTTOMAC NDT SERVICES 2000LEVEL ll MT PT UT RTMETCO 03/2004




Education
EDUCATION 1986 COLLEGE OF OCEANEERING US-CALIFORNIA-WILMINGTON
Certification
REFINERY PROCESS AND INSPECTION COURSESAFETY AND TERMINOLGYMECHANICAL AND CORROSIVE DETECTION PROCESS

1982 SPARTAN SCHOOL OF AERONAUTICS US-OKLAHOMA-TULSA
Certification
NON-DESTRUCTIVE TESTING TECHNICIAN COURSE;ASNT LEVEL II MT,PT,UT,RT,VTAWS/ASM WELDING INSPECTION AND QUALITY CONTROL
Experience
EXPERIENCE 01/2004 – 03/2004 METCO HOUSTON,TX
NDT INSPECTOR
NDT SUPPORT FOR GENERATION STATION. TURBIN OUTAGE AT ORMOND BEACH, CA.OWNED BY RELIANT ENERGY.


11/1997-06/2003 TOMAC NDT BENICIA,CA

NDT INSPECTOR
BASELINE DATA FOR SONIC SURVEY FOR COMPLETE REFINERY LOCATED IN SALT LAKE CITY,UT TESORO REFINERYIN HOUSE RADIOGRAPHY

11/1997 - 5/2003 PETRO CHEM TOSCO AVON MARTINEZ,CA
INSPECTOR
MT,PT,UT,RT AT SHELL,MARTINEZ TOSCO,AND RODEO TOSCO AVONKOCH REFINERY IN CORPUS CHRISTI,TEXASASHLAND MARATHON IN CANTON,OHIO

11/1997 - 5/2003 CONTINENTAL TESTING AND INSPECTION BENECIA,CA
INSPECTOR
PERFORMED SONIC INSPECTION ON OCEAN FLEET IN SAN FRANCISCO DRY DOCKRT ON STORAGE TANKS AT CHEVRON IN RICHMOND,CACONTRACTOR AS NEEDED

7/1997 - 10/1997 ULTRASONIC FIELD SERVICES CONCORD,CA
INSPECTOR
MT,PT,UT,RT PERFORMED AS PROCTOR & GAMBLE IN SACRAMENTO,CACONTRACTOR AS NEEDED

6/1997 - 4/2003 TC INSPECTION PINOLE,CA
INSPECTOR
VISUAL INSPECTION,MT INSPECTION FOR SANTA ROSA RECHARGE PROJECT STARTING IN SANTA ROSA,CA ENDING IN CLEARLAKE, CA 9 MOS DURATION

5/1997 - 5/2003 TOMAC BENECIA,CA
INSPECTOR
INDUSTRIAL RADIOGRAPHY FOR CONCRETE,WELD QUALITY, AND WALL SHOT THICKNESS SHOOTINGULTRASONIC INSPECTION FOR SHIPPING INDUSTRY AS PER COAST GUARD AND ABS REQUIREMENTSCONTRACTOR AS NEEDED

12/1996 - 6/1997 RAY ESTLING SPARKS,NV
LANDSCAPER
BUILDING AND LANDSCAPE MAINTENANCE OF COMMERCIAL PROPERTIES

1/1995 - 12/1996 JOHN ASCUAGA NUGGET SPARKS,NV
LANDSCAPER
LANDSCAPE MAINTENANCE OF ALL NUGGET COMMERCIAL & RESIDENTIAL PROPERTIES

10/1994 - 12/1994 RENO LAWN RENO,NV
LANDSCAPER
LANDSCAPE MAINTENANCE, INSTALLATIONS, IRRIGATION, AND XERISCAPE

6/1994 - 8/1994 RI STEWART CONSTRUCTION RENO,NV
CARPENTER
ROUGH & FINISH CARPENTRY

5/1992 - 5/1994 LONEWOLF GENERAL RENO,NV
OWNER
SPECIALIZED IN CUSTOM LANDSCAPE DESIGN OF RESIDENTIAL PROPERTIES

9/1990 - 4/1992 PEZONELLA & ASSOCIATES RENO,NV
SPECIAL INSPECTOR
NON-DESTRUCTIVE TESTING & INSPECTION OF SOILS, CONCRETE, & ASPHALT

4/1990 - 9/1990 SEA CONSULTING RENO,NV
SPECIAL INSPECTOR
PERFORMED ULTRASONIC WELDING INSPECTIONS

11/1989 - 4/1990 DEFENSE SYSTEMS/HI SHEAR RENO,NV
INSPECTOR
LEVEL II RADIOGRAPHERRADIOGRAPHY ON EXPLOSIVES & REPELLANTSTRAINED IN ELECTRICAL INSPECTION OF DETONATING DEVICESHELIUM LEAK TESTINGIN-PROCESS PRODUCTION TESTING

6/1989 - 11/1989 SIERRA CAST PFI RENO,NV
INSPECTOR
NDT & WELDING INSPECTIONX-RAY,MAGNETIC PARTICLE, AND PENETRANT TESTING FOR THE DEPARTMENT OF DEFENSE

10/1988 - 6/1989 RICHARDSON X-RAY ALHAMBRA,CA
INSPECTOR
NDT INSPECTIONPOWER PLANT INSPECTION OF BOILERS & COMPONENTS, TURBINES, AND DIAPHRAGMS

4/1988 - 10/1988 TOMAC NDT SERVICES GARDEN GROVE,CA
INSPECTOR
NDT INSPECTION

5/1986 - 4/1988 ULTRASONIC FIELD SERVICES CARSON,CA
INSPECTOR
NDT INSPECTIONSUPERVISED EMPLOYEESUNION 76,ARCO,CHAMPLEN,TEXACO,CHEVRON,AND MOBILE REFINERIESFIRE DAMAGE INSPECTION USING HARDNESS TESTING OF STRUCTURAL STEELR AND R OF ELECTRICAL COMPONENTS OF ULTRASONIC UNITS AS NEEDED

11/1985 - 5/1986 CONTINENTAL TESTING & INSPECTION SIGNALL HILL,CA
INSPECTOR
WELDING INSPECTION USING NDT TECHNIQUESVISUAL INSPECTION ON POWER PIPING, VESSELS, AND STRUCTUAL STEEL AT ARCO REFINERY

4/1983 - 11/1985 MOBILE INSPECTION SANTA FE SPRINGS,CA
INSPECTOR
NDT INSPECTION OF BOTH NUCLEAR AND FOSSIL FUEL GENERATION STATIONS ON WEST COASTSALT RIVER PROJECT, SOUTHERN CAL EDISON, PG&E
Evident Ultrasonic Inspection Equipment