Workpad Industrial Data Solutions IoT
Cotract IRATA/ API Inspector
To see contact info and more resumes Get a Level II Subscription or Call (415) 469-0489.
State: IN Indiana
Country: United States
Status:
I am willing to Travel.
Currently working but always looking.
I am willing to work overseas.
I prefer temp jobs.
Certifications
Nondestructive/Inspection Certificates
o API 570 Piping Inspector Cert# 45221
o API 510 Pressure vessel Inspector Cert# 57144
o API 577 Welding inspection & metallurgy specialist Cert# 65688
o Indiana In-service / Repair PEI Certified Inspector Cert# PEI-103-IS/RQ.
o Liquid Penetrant II Certificate
o Magnetic Particle II Certificate
o Visual Examination II Certificate
Education
General Education Development (GED) Diploma
o Graduation Date January 2007

MT,PT,UTT & Radiation Safety Training
O October 2006

RT I & II Training
o June 2008

Codewest API 570 Exam Preparation Course
o May 2012

Ivy Tech NBIC Exam Preparation Course
o April 2014

MSTS API 510
o January 2015

IRATA LVL 1
o May 2016
Experience
BP Whiting Refinery Whiting, IN March 2017 - Present

NBIC PEI Inspector PEI-103-IS/RQ, API 510 #57144,API 570 #45221, API 577 #65688, RFI. IRATA LVL 1 # 1/101828
Performing & maintaining compliance of boiler, pressure vessel & piping inspections for the 11 Pipe Still Crude Processing Unit.
Performing in depth CUI inspection & analysis for CUI susceptible equipment throughout the unit.
Developing inspection plans and execution of potentially near retirement piping &/or equipment by manipulating pcms to show all near retirement components & performing advanced NDE techniques to determine development of the assumed corrosion per pcms data & possible life expectancy in coordination with scheduled unit shutdowns.
Coordinating with TAR groups to properly prepare for scheduled unit outages, including the required equipment in need of inspection during the outage, required cleaning plan for inspection & NDE & possible repairs to be prepared for due to previous equipment history or known issues found while in service via on line inspections.
Working hand in hand with engineering to utilize proper inspection techniques & frequencies for piping & equipment with high internal corrosion potential.
Reporting directly to the unit superintendent with advancements we've made since my arrival to become a more proactive inspection department & reporting lopc saves we have made as a direct result of the advancements we've made to be proactive & utilize more inspection tools the refinery has previously neglected to support in favor of less effect but less costly techniques.



Team Industrial Services Hammond, IN April 2015- March 2017

Indiana NBIC Inspector #1993, API 510 #57144 ,API 570 # 45221,API 577 #65688 VT,MT,PT LVL II, IRATA LVL I
Reviewing API external inspections of piping & pressure vessels performed by other contract API inspectors & determining path forward on recommendations based on the associated risk per API 580 & the owner users risk matrix.
Performing Boiler & vessel internals & making repair or remediation recommendations in accordance with the associated code.
 Reviewing weld quality control form packages during unit outages to assure all required welding & testing documentation has been accounted for & is without inaccuracies.
Performing initial internal & external inspections as well as assigning CML designations for plants with no previous documented inspection history.
 performing in depth CUI inspection & analysis for CUI susceptible piping.

BP Whiting Refinery Whiting, IN December 2013- April 2015

NBIC Inspector, API 510, API 570, RFI, NDE Technician
Performing compliance boiler, pressure vessel & piping inspections for the OSBL & OMD.
Performing in depth CUI inspection & analysis for CUI susceptible piping throughout the refinery.
Performing typical turnaround inspections such as vessel internal & hydrostatic pressure testing evaluations.
Reviewing radiographic weld quality film performed by contractors to ensure quality in film & interpretation.
Performing MT, PT, UTT, PMI, & VT Inspections.

Team Industrial Services Hammond, IN April 2013- December 2013

Radiographer II, API 570, NDE Technician
Performed API 570 in BP whiting refinery.
Performed radiographic inspections for thickness/corrosion monitoring & weld quality.
Trained assistant radiographers in radiographic technique, procedure requirements, acceptance criteria & film interpretation.
Performed MT, PT, UTT, PMI, & VT Inspections.

Acuren Inspections - Tinley Park, IL April 2012 April 2013

Radiographer II, API 570, NDE Technician
Performed radiographic inspections for thickness/corrosion monitoring & weld quality.
Trained assistant radiographers in radiographic technique, procedure requirements, acceptance criteria & film interpretation.
Performed MT, PT, UTT, PMI, & VT Inspections.


Mistras Group Hobart, IN July 2009 April 2012

Project Manager, Site Safety Manager, Radiographic Film Interpreter, Radiographer II, NDE Technician.
Project Manager for a new integrated gasification combined cycle Duke Energy Power Plant.
Received dispersed and documented all requests & reports for NDE from all welding companies throughout the project.
Tracked employee time & NDE materials for billing to owner/user.
Attended weekly Project Manager Meetings to discuss production & advancements throughout the Project.
Maintained safety documents, performed audits, lead training, and helped maintain a safe working environment resulting in an OSHA recordable rate of 0.00 for 2011-2012.
Reviewed all radiographic film for quality & various code acceptances.
Reviewed all NDE reports from 2011 to 2012 to verify they were properly written & included all relevant & correctly documented information.
Performed radiographic inspections for weld quality.
Trained assistant radiographers in radiographic technique, procedure requirements, acceptance criteria & film interpretation.
Performed MT, PT, UTT, PMI, & VT Inspections.

Team Industrial Services Hammond, IN January 2008- July 2009

NDE Technician, Radiographer
Performed radiographic inspections for thickness/corrosion monitoring & weld quality.
Performed MT, PT, UTT, PMI, & VT Inspections.

Elite Inspections Hobart, IN October 2006- December 2007

Ultrasonic Thickness Evaluation II & RT asst.
Performed UTT & assisted in RT,MT,& PT.
Comments
Computer Literacy
o Microsoft Office
o Lotus Notes
o PCMS
o IDMS
o Fastlook 12.0

Professional References

Mr. Ian Harrison
BP Whiting Inspection Superintendent
219.241.1685
Ian.Harrison3@uk.bp.com

Mr. Robert Phelan
Citgo Lemont Unit Inspector
Cell: 708.207.3374
Phelan.Robert@gmail.com

Mr. Ben Skwirut
Exxon Mobil Joliet Loss Prevention System Coordinator
Cell: 815.955.8842
Benjamin.Skwirut@exxonmobil.com